Comparing paraffined and deparaffinized breast cancer tissue samples and an analysis of Raman spectroscopy and infrared methods
PBN-AR
Instytucja
Instytut Fizyki Jądrowej im. Henryka Niewodniczańskiego Polskiej Akademii Nauk
Informacje podstawowe
Główny język publikacji
en
Czasopismo
INFRARED PHYSICS & TECHNOLOGY
ISSN
1350-4495
EISSN
Wydawca
DOI
URL
Rok publikacji
2016
Numer zeszytu
Strony od-do
217-226
Numer tomu
76
Identyfikator DOI
Liczba arkuszy
Autorzy
(liczba autorów: 7)
Pozostali autorzy
+ 6
Słowa kluczowe
en
Breast cancer
Raman spectroscopy
Fourier transform infra red spectroscopy
Chemotherapy
Methods
AMIDE-I
TOMOGRAPHY
BANDS
IMMUNOHISTOCHEMISTRY
ULTRASONOGRAPHY
ELASTOGRAPHY
ABSORPTION
MUTATIONS
PROTEINS
LESIONS
Streszczenia
Język
en
Treść
Breast cancer makes up a quarter of all cancer in women, which is why research into new diagnostic methods and sample preparations need to be developed at an accelerated pace. Researchers are looking for diagnostic tools to detect when an individual has cancer cells and use that information to see what measurements and approaches can be used to take further diagnostic steps. The most common method of sample preparation is the imbibing of tumor tissue in paraffin, which can produce a background for spectroscopic measurements in the range of 500-3500 cm(-1). In this study we demonstrated that proper preparation of paraffin-embedded specimens and the measurement methodology can eliminate paraffin vibration, as was done in the work Depciuch et al. 2015. Thanks to this spectroscopic technique there may become a reliable and accurate method of diagnosing breast cancer based on the evidence found from the prepared samples. The study compared the results obtained through Raman spectroscopy and FTIR (Fourier Transform Infrared) measurements of healthy and cancerous breast tissues that were either embedded in paraffin or deparaffinized. The resulting spectrum and accurate analysis led to the conclusion that the appropriate measurement of the background and the elimination of peaks from the paraffin had the greatest impact on the reliability of-results. Furthermore, after the accurate, detailed studies FTIR and Raman spectroscopy on samples of breast tissue that were deparaffinized or embedded in paraffin, including a complete analysis of the peak after transformation Kramers Kroning (KK), it was found that sample preparation did not affect the result obtained by measuring the reflectance in the mid-infrared range, and that this only had a minimal effect relating to the intensity obtained by the measurement of the Raman peak. Only in special cases, when Raman spectroscopic methods are used for research to find the peculiarities of the spectra, are deparaffinization recommended, in order to attain more detailed results that could be crucial in understanding the process of carcinogenesis.