Advances in design and testing of limited angle optical diffraction tomography system for biological applications
PBN-AR
Instytucja
Wydział Mechatroniki (Politechnika Warszawska)
Książka
Tytuł książki
Quantitative Phase Imaging II, Vol. 9718
Data publikacji
2016
ISBN
9781628419528
Wydawca
SPIE
Publikacja
Główny język publikacji
en
Tytuł rozdziału
Advances in design and testing of limited angle optical diffraction tomography system for biological applications
Rok publikacji
2016
Strony (od-do)
971825-1 - 971825-9
Numer rozdziału
Identyfikator DOI
Liczba arkuszy
0.5
Hasło encyklopedyczne
Słowa kluczowe
en
Tomographic phase microscopy, digital holography, diffraction tomography, quantitative phase imaging, 3D imaging, refractive index, two-photon polymerization
Konferencja
Indeksowana w Scopus
nie
Indeksowana w Web of Science Core Collection
tak
Liczba cytowań z Web of Science Core Collection
Nazwa konferencji (skrócona)
Nazwa konferencji
Quantitative Phase Imaging II
Początek konferencji
2016-02-13
Koniec konferencji
2016-02-13
Lokalizacja konferencji
Kraj konferencji
US
Lista innych baz czasopism i abstraktów w których była indeksowana
Streszczenia
Język
en
Treść
Optical diffraction tomography has been steadily proving its potential to study one of the hot topics in modern cell biology – 3D dynamic changes in cells’ morphology represented with refractive index values. In this technique digital holography is combined with tomographic reconstruction and thus it is necessary to provide projections acquired at different viewing directions. Usually the Mach-Zehnder interferometer configuration is used and while the object beam performs scanning, the reference beam is in most cases stationary. This approach either limits possible scanning strategies or requires additional mechanical movement to be introduced in the reference beam. On the other hand, spiral or grid scanning is possible in alternative common-path or Michelson configurations. However, in this case there is no guarantee that a specimen is sparse enough for the object to interfere with an object-free part of the beam. In this paper we present a modified version of Mach-Zehnder interferometer-based tomographic microscope, in which both object and reference beam are subject to scanning using one scanning device only thus making any scanning scenario possible. This concept is realized with a custom-built optical system in the reference beam and is appropriate for mechanical as well as optical scanning. Usually, the tomographic reconstruction setups and algorithms are verified using a microsphere phantom, which is not enough to test the influence of the distribution of the projections. In this work we propose a more complex calibration object created using two-photon polymerization.
Inne
System-identifier
WUTf16e90a6a590485a9fd8304b53d37c10
CrossrefMetadata from Crossref logo
Cytowania
Liczba prac cytujących tę pracę
Brak danych
Referencje
Liczba prac cytowanych przez tę pracę
Brak danych